Specifications:
Details | Specification |
Continuous discharge current | 30(MAX)A |
Instantaneous discharge current | 70A |
Charging voltage
|
16.8V |
Charging current | 30(MAX)A |
Overcharge detection voltage | 4.28±0.05V |
Overcharge protection delay | 0.1S |
Overcharge release voltage | 4.08±0.01V |
Battery balance detection voltage | 4.2±0.025V |
Battery balance release voltage | 4.2±0.05V |
Electricity balance current | 60±5mA |
Overdischarge detection voltage | 2.55±0.08V |
Overdischarge detection delay | 0.1S |
Overdischarge release voltage | 3.0±0.1V |
Overcurrent detection voltage | 150mV |
Overcurrent detection delay | 9mS |
Overcurrent protection current | 75±5A |
Overcurrent protection release condition | Disconnect load |
Short circuit protection condition | External load short circuit |
Short circuit detection delay | 250uS |
Short circuit protection release condition | Disconnect the load switch |
Temperature protection | / |
Main circuit conduction internal resistance | ≤15mΩ |
Working current
|
≤30uA |
Sleep current (when the battery is over-discharged) | ≤10uA |
Operating temperature
|
-30℃~+80℃ |
Size | 45x56mm |
Main function:
Over charge protection, over discharge protection function, short circuit protection
function, over current protection function, band balance.
Interface definition:
Charging port of the plate and the discharge port is the same, both positive and B- connecting
battery”-“, P- charging port and port on the negative electrode;
B-, N-, P- pads are all over the hole, the hole diameter of the pad is 3.5mm;
The battery charging detection interface with DC output in the form of needle. Do the same mouth
when the N- is not wiring.