Description:
Model: K24
Media: methanol diesel fuel kerosene chemical liquid urea water
Importers: 1 inch internal thread
Length: 103MM
Measurement accuracy: ± 1%
Repeatability: ± 0.5%
Maximum working pressure: 20BAR
Operating voltage: 2.3-3.3V
Standby time: 2 years
Flow range: 10-120L / MIN
Single count: 0.00-999.9
The total cumulative number: 0.00-999999.9
Unit: L / L, gal / GAL, pint / PTS, quart / QTS
Single measurement cleared: RESET
Features:
1.Control panel with modular design, fully functional, simple structure, convenient operation.
2.Can be widely used in petroleum, chemical, pharmaceutical, transportation, food to be industrial and commercial.
Setting units of measurement:
In the standby mode, or raise the amount of current display state
Press CAL + RESET button for 5 seconds
Enter unit conversion settings, press the RESET button
Followed by LTR → GAL → PT → QT → LTR choose the unit of measurement
While the cumulative filling volume displayed in the current unit of measure conversion after
Press the MENU key for 3 seconds to exit the unit conversion settings.